1.Main beam H-steel tightly secured to the building floor for the main support for the device structure.
2.Each H-steel has 2 groups of up wheel and 1 group of under wheel completely attached to the H-beam flange rolling. Reducing structural change and damage.
3.Main elevator structure use channel steel [100X50X5/7.5t welded joints. Elevator chassis use 3.0t pattern steel.
4.Both sides of elevator barrier use 1.2t laminated steel parts (1470mmH).
5.Driving system:
A.Freight elevators use ψ160 hydraulic (25HP Oil-immersion main engine) to matchR120-double-row chains indirectly drive. 15M speed run up and down per minute.
B.Rotary system uses motor-type (1/2HP×4P) directly drive wheel. 2rpm speed rotate. |